Low Temperature Actuation Probe (LTAP)

Low Temperature Actuation Probe (LTAP)
Low Temperature Actuation Probe (LTAP)

1/2" NPT Probe Connection
MAWP 600 PSI (41.4 bar)

Description

The LTAP Series Low Temperature Actuation Probe is a temperature controlled pneumatic two-way valve. The device utilizes a pressurized copper probe which reacts to fluid temperature and opens a passageway in the top control head as the fluid temperature approaches the device temperature setpoint. The LTAP Series can be installed on cryogenic systems to protect end users when draw rates are higher than system capacity or ambient conditions are much colder than normal.

Features

  • Highly Accurate: Setpoint Tolerance of ±3°F
  • Quick Open: Control head opens quickly at desired setpoint, less than 3°F from first bubble to full open
  • Repeatable and Reliable: Designed to activate at temperature setpoint repeatedly and reliably in a wide range of ambient conditions
  • Cleaned for O2 Service: Assembled Cleaned for Oxygen Service as Standard
  • Discharge to Atmosphere or a Wide Variety of Inlet and Outlet Piping Configurations
  • Robust Design: Solid brass design with Working Pressure up to 600 PSIG

Technical Data

  • Maximum Probe Pressure: 600 PSIG (41.4 bar)
  • Maximum Control Head Pressure: 600 PSIG (41.4 bar)
  • Temperature Setpoint Range: -40°F to 0°F
  • Setpoint Tolerance: Nominal ±3°F
  • Full Open: Within -3°F of Initial Open
  • Exposed Fluid Temperature Range: -320°F to +150°F
  • Ambient Temperature: -60°F to +150°F
  • Control Head Full Open Cv: 0.02
  • This Products is NOT a Safety Device or Safety Accessory

Click here to download LTAP Series product literature

Click here to download LTAP Series user instructions